Punch Biopsy Of Iris Lesions: A Novel Technique For Obtaining Histology Samples

Pe’er J, Blumenthal EZ, Frenkel S. Br J Ophthalmol. 2007 May;91(5):660-2. Department of Ophthalmology, Hadassah-Hebrew University Medical Center, PO Box 12000, 91120 Jerusalem, Israel. peer@md.huji.ac.il ABSTRACT: AIM: To obtain iris biopsy samples of sufficient quality and quantity for histopathological analysis using a novel punch biopsy technique. METHODS: Two patients underwent iris tumour biopsy at an […]

Punch Biopsy Of Iris Lesions: A Novel Technique For Obtaining Histology Samples Read More »

Early Transient Visual Acuity Loss After Lasik Due To Steroid-Induced Elevation Of Intraocular Pressure

Frucht-Pery J, Landau D, Raiskup F, Orucov F, Strassman E, Blumenthal EZ, Solomon A. J Refract Surg. 2007 Mar;23(3):244-51. Department of Ophthalmology, Hadassah-Hebrew University Medical Center, Jerusalem, Israel. ABSTRACT: PURPOSE: To report the clinical course of early transient reduction of uncorrected visual acuity (UCVA) after LASIK surgery resulting from steroid-induced elevation of intraocular pressure (IOP).

Early Transient Visual Acuity Loss After Lasik Due To Steroid-Induced Elevation Of Intraocular Pressure Read More »

Morphometric Analysis Of Human Peripapillary Retinal Nerve Fiber Layer Thickness

Cohen MJ, Kaliner E, Frenkel S, Kogan M, Miron H, Blumenthal EZ. Invest Ophthalmol Vis Sci. 2008 Mar;49(3):941-4. Department of Ophthalmology, Hadassah-Hebrew University Medical Center, Jerusalem, Israel. ABSTRACT: PURPOSE: The peripapillary retinal nerve fiber layer (RNFL) thickness pattern in the normal human eye has been well characterized using data obtained with scanning laser polarimetry and

Morphometric Analysis Of Human Peripapillary Retinal Nerve Fiber Layer Thickness Read More »

Measuring Choroidal Melanoma Basal Diameter: Using Ultrasound Vs. A New Wide–angle Fundus Camera

J.J. Pe’er, C. Sancho, J. Cantu, S. Eilam, I. Barzel, M. Shulman and E.Z. Blumenthal Invest Ophthalmol Vis Sci 2004;45: E-Abstract 1223. © 2004 ARVO 1223 – B34 Department of Ophthalmology, Hadassah University Hospital, Jerusalem, Israel Commercial Relationships: J.J. Pe’er, None; C. Sancho, None; J. Cantu, None; S. Eilam, None; I. Barzel, None; M. Shulman, None; E.Z. Blumenthal, None. Grant Identification: none ABSTRACT: PURPOSE: Largest basal diameter of

Measuring Choroidal Melanoma Basal Diameter: Using Ultrasound Vs. A New Wide–angle Fundus Camera Read More »

Visual Function-Specific Perimetry For Indirect Comparison Of Different Ganglion Cell Populations In Glaucoma

Sample PA, Bosworth CF, Blumenthal EZ, Girkin C, Weinreb RN. Invest Ophthalmol Vis Sci. 2000 Jun;41(7):1783-90. Department of Ophthalmology, University of California at San Diego, La Jolla 92093-0946, USA. ABSTRACT: PURPOSE: To compare short-wavelength automated perimetry, frequency-doubling technology perimetry, and motion-automated perimetry, each of which assesses different aspects of visual function, in eyes with glaucomatous

Visual Function-Specific Perimetry For Indirect Comparison Of Different Ganglion Cell Populations In Glaucoma Read More »

Test-Retest Variability In Visual Field Testing Using Frequency Doubling Technology

Horani A, Frenkel S, Blumenthal EZ. Eur J Ophthalmol. 2007 Mar-Apr;17(2):203-7. Department of Ophthalmology, Hadassah University Hospital, and Hebrew University-Hadassah Medical School, Jerusalem 91120, Israel. ABSTRACT: PURPOSE: To quantify the magnitude of test-retest variability (TRV) for normal subjects in serial visual fields (VF) using the frequency doubling technology (FDT) instrument. METHODS: Twenty-one healthy adults, aged

Test-Retest Variability In Visual Field Testing Using Frequency Doubling Technology Read More »

The Effect of Pupil Dilation on Scanning Laser Polarimetry with Variable Cornea Compensation

E.Z. Blumenthal, A. Horani and S. Frenkel Invest Ophthalmol Vis Sci 2004;45: E-Abstract 3311. © 2004 ARVO 3311 – B946 Dept of Ophthalmology, Hadassah University Hospital, Jerusalem, Israel Commercial Relationships: E.Z. Blumenthal, Laser Diagnostic Technologies F; A. Horani, None; S. Frenkel, None. Grant Identification: none ABSTRACT: PURPOSE: Scanning laser polarimetry is routinely performed through a non–dilated pupil, since scanning through

The Effect of Pupil Dilation on Scanning Laser Polarimetry with Variable Cornea Compensation Read More »

Inter-Device Reproducibility of the Scanning Laser Polarimeter with Variable Cornea Compensation

E.Z. Blumenthal and S. Frenkel Invest Ophthalmol Vis Sci 2003;44: E-Abstract 3390. © 2003 ARVO 3390 – B93 Dept of Ophthalmology, Hadassah University Hospital, Jerusalem, Israel Commercial Relationships: E.Z. Blumenthal, Laser Diagnostic Technologies F; S. Frenkel, None. ABSTRACT: PURPOSE: To evaluate the inter-device reproducibility of retinal nerve fiber layer (RNFL) thickness measurements obtained with the commercially available

Inter-Device Reproducibility of the Scanning Laser Polarimeter with Variable Cornea Compensation Read More »

Short-Wavelength Automated Perimetry And Standard Perimetry In The Detection Of Progressive Optic Disc Cupping

Girkin CA, Emdadi A, Sample PA, Blumenthal EZ, Lee AC, Zangwill LM, Weinreb RN. Arch Ophthalmol. 2000 Sep;118(9):1231-6. Glaucoma Center, University of California-San Diego, 9500 Gilman Dr, La Jolla, CA 92093-0946, USA. ABSTRACT: OBJECTIVE: To compare progression in short-wavelength automated perimetry (SWAP) and white-on-white (standard) perimetry in eyes with progressive glaucomatous changes of the optic

Short-Wavelength Automated Perimetry And Standard Perimetry In The Detection Of Progressive Optic Disc Cupping Read More »

Retinal Nerve Fibre Layer Imaging Compared With Histological Measurements In A Human Eye

Blumenthal EZ, Parikh RS, Pe’er J, Naik M, Kaliner E, Cohen MJ, Prabakaran S, Kogan M, Thomas R. Eye (Lond). 2009 Jan;23(1):171-5. Epub 2007 Aug 24. Department of Ophthalmology, Hadassah-Hebrew University Medical Center, Jerusalem, Israel. eblumenthal@md.huji.ac.il ABSTRACT: PURPOSE: A feasibility study comparing retinal nerve fibre layer (RNFL) thickness values obtained with imaging devices against RNFL

Retinal Nerve Fibre Layer Imaging Compared With Histological Measurements In A Human Eye Read More »