Blumenthal EZ.

Surv Ophthalmol. 1995 Nov-Dec;40(3):225-8.
Department of Opthalmology, Hadassah University Hospital, Jerusalem, Israel.

ABSTRACT:

Adjusting the slit-lamp eyepiece rings is perceived by some to be insignificant for achieving adequate focus. Others assume that these rings should be set only to compensate for one’s refractive error. Observations are presented concerning the eyepiece scale setting during routine examinations, slit-lamp mounted YAG and Argon laser procedures and during opthalmic surgery. Diagrams illustrate the optical basis of these observations. Factors influencing optimal eyepiece ring setting, besides ametropia, include slit-lamp misalignment (variations in calibration) as well as unconscious accommodation. An inaccurate setting cannot be fully compensated by adjusting the slit-lamp joy-stick. When an incorrect setting is used, while using oblique illumination, it becomes impossible to focus on details placed at the center of the viewfinder. In addition, irrespective of joy-stick position, it is impossible to view an oblique slit transecting the cornea in perfect focus. An accurate setting, as a whole, results in sharper images throughout the slit-lamp examination. Differences between individual instruments make it necessary to reset the eyepieces for each eye and for each individual instrument. Methods are described for evaluating the need for readjustment, as well as a simple technique for calibration in the absence of a focusing rod.

המאמר המלא- כקובץ PDF

Figures from this article:

 

אבחנה

אתר זה נכתב ע”י פרופ’ איתן בלומנטל. באתר תמצאו אינפורמציה מעמיקה על האבחון והטיפול בגלאוקומה ובקטרקט. האינפורמציה באתר איננה תחליף לייעוץ רפואי.

פוסט קשור

PDF icon 1
Risk Factors and Incidence of Ocular Hypertension After Penetrating Keratoplasty
Faik Oruc¸oglu, MD, Eytan Z. Blumenthal, MD, Joseph Frucht-Pery, MD, and Abraham Solomon, MD Journal of Glaucoma. 2013 Feb 19. Kudret Eye Hospital, Istanbul, Turkey Department of Ophthalmology, Hadassah-Hebrew...
PDF filing cabinet
רשימת פרסומים מדעיים של פרופ' איתן בלומנטל
ORIGINAL RESEARCH PAPERS Blumenthal EZ. Adjusting the slit-lamp oculars: An unnecessary burden or a must?  Survey of Ophthalmology 1995;40(3):225-228. Abstract Full-text (PDF) Blumenthal EZ, Serpetopoulos...
PDF icon 1
On Focusing The Slit-Lamp: Part I. An Inaccurate Ocular Setting–What Is There To Lose?
Blumenthal EZ, Serpetopoulos CN. Surv Ophthalmol. 1998 Jan-Feb;42(4):351-4. Department of Ophthalmology, Hadassah University Hospital, Jerusalem, Israel. ABSTRACT: Adjustments of the diopter rings on the...
PDF icon 1
Glaucomatous-Like Cupping Associated With Slow-Growing Supra-Sellar Intracranial Lesions
Blumenthal EZ, Girkin CA, Dotan S. Neuro-Ophthalmology. 2006;30:111-115. Department of Ophthalmology, Hebrew University-Hadassah Medical Center, Jerusalem, Israel. eblumenthal@md.huji.ac.il ABSTRACT: PURPOSE:...
PDF icon 1
On Focusing The Slit-Lamp: Part II. “The Fading-Slit Test” Verifying The Ocular Setting
Blumenthal EZ, Serpetopoulos CN Surv Ophthalmol. 1998 Jan-Feb;42(4):355-7. Department of Ophthalmology, Hadassah University Hospital, Jerusalem, Israel. ABSTRACT The focusing-rod test is considered the...